Web Analytics

Dometic Ac Control Box Wiring

If the system has an electronic control box plug FIG. Wire diagram is inside the control box cover.

Dometic Comfort Control Center Ii Multi Zone Kit Rv Rv Parts Country Rv Rv Parts Multi

After that its basically plug and play Multiple ACs Multiple models furnaces and fan settings all controlled by daisy chaining with modified 4 stand phone cable.

Dometic ac control box wiring. This is a remarkable piece of engineering. Just jack them together tell them which unit it is with dip switches. This control box has wires for a 12V connection furnace control load shed and 120V connection.

CONNECTING 120V AC TO THE SZLCD CONTROL RELAY BOX WHETHER YOU HAVE A SEVEN 7 OR 3 WIRE THERMOSTAT CABLE IS AS FOLLOWS. Strip about ½ inch 127cm of insulation from the white wire and from the BROWN wire from EasyStart. It inserts into the fins on the unit above the control box.

The tool is available anytime and is enhanced regularly. If you installed the new style control box that is gray then the furnace wires go into the side of the control box. Follow the white wire from the compressor into the electric box to the top of the run capacitor as indicated by the green arrow in Figure 18.

Route a copper with ground 120 Vac supply wire from the time delay fuse or circuit breaker box to the roof opening. The proper size wire can be determined from chart on page 4. Replacing an older single zone Dometic analog control box and thermostat with a new style digital one.

All Initial 509 South Poplar Street Installations Must Be Approved By Dometic Corporation LaGrange IN 46761 260-463-4858 CANADA Dometic Distribution 866 Langs Drive. Also it is a good idea to either use an in-line fuse or an ARP Circuit Breaker in-line with the power supply to the control box. The Dometic for Business portal provides comprehensive information and ordering capabilities for products repair parts and accessories marketing and sales resources support contacts training account information and more.

It owes not matter which goes where just plug them in. It keeps the unit from icing up. Dometic 3314851000 Air Distribution Box w Manual Controls.

This assembly allows for cooling operation heating operation if your AC is compatible fan operation and discharge open and close. Wiring diagram for 3107546008. First turn off the main breaker and the battery disconnect to cut all power to the ac unit.

Variety of dometic ac wiring diagram. View the pictures to know which wires you will need to identify to hook into the relay box. If you look on the side on the control box toy will see where two male spades are located.

This is a ceiling control and distribution kit for compatible Dometic Air Conditioners. Page 1 3106615 Air Distribution Box Kit and 3109228001 Duo-Therm Comfort Control Center SERVICE OFFICE Dometic Corporation This Unit Is Designed For OEM Installation. The ARP yellow wire is connected to the violet wire that supplies power to the Dometic control box eyebrow board.

Before cutting off the old wires to the control box Identify 12 volt power in heater. Only 3 wires are needed to this thermostat. Then i opened the control unit and the wiring diagram was on the inside afterdigital dometic duo therm brisk 3 button thermostat kit.

Its worth the time and effort. 17 AC Power Models Using Electronic the 6 pin electrical cord from the unit into the Control Kit Supply mating connector in the electronic control box. The plug is polarized and will only fit in one di- rection.

Use it to connect all Dometic AC models to 5 button Thermostat. Route a copper with ground 120 VAC supply wire from the time delay fuse or circuit breaker box to the roof opening. They are for the furnace wires.

Your new thermostat only needs 3 wires. The control board inside the control box is compatible with Duo-Therms original Confort Control Center will not work with CCC2 Thermostats. The ARP is shown spliced into the power wire where the ARP red wire is connected to the power source the screw terminal positive.

Make sure all power sources are disconnected. CONNECTING V AC TO THE SZLCD CONTROL RELAY BOX WHETHER YOU. This kit will operate most any single Dometic Duo-Therm air conditioner with a 6-pin plug and a furnace but before ordering be sure to identify the wires.

4 This is the Dometic control box see 3 for wiring. Disconnect the white wire and cut off the connector on the end. A wiring diagram is a simplified traditional photographic representation of an electrical circuit.

Page 13 INSTALLATION INSTRUCTIONS 5. Air Distribution Box Wiring Diagram This air conditioner hereinafter referred to as unit or product is design and intended for. Features help protect your AC from short cycling.

Compatible with a 6 pin air conditioner plug 3 pin heat strip plug optional and a 2x RJ-11 plug that goes to your thermostat and other additional AC. Installation and Operating Manual. 457915 B57915 459516 B59516 540315 H540315 540316 H540316 640312 640315.

Camera httpsamznto2K3aW0TCordless Mic httpsamz. Blue wires that you have just plugged into the control relay box. The Dometic Single Zone Liquid Crystal DisplaySZLCD PNs.

It reveals the elements of the circuit as simplified forms as well as the power and also signal connections in between the tools. The wiring can be kind of tricky but the wiring diagram is in the lid. We would like to show you a description here but the site wont allow us.

Dometic 3316234 700 Single Zone Ct Thermostat W Control Board Kit Cool Furnace Heat Pump White Thermostat Heat Pump Air Conditioner Heating Furnace

Dometic 3313189000 Rv Air Conditioner Heat Cool Thermostat Control Kit Thermostat Wiring Rv Air Conditioner Ac Wiring

Dometic 3316250 700 Single Zone Ct Thermostat Cool Furnace White Thermostat Heat Pump Thermostat Wiring

Dometic Duo Therm 3310009 000 4 To 5 Button Comfort Control Center Upgrade Kit Heat Pump System Control Electrical System

Dometic Duo Therm 3315332 005 Oem Brisk Ii Fan Motor Assembly Fan Motor Ferrari 288 Gto Ferrari Convertible